AVC-DVR is an innovative voltage stabilizing system designed to mitigate and eliminate the
effects of electrical disturbances such as severe voltage drops and spikes in critical industrial
processes.
2.How AVC-DVR works:
The main components of the AVC-DVR:
*Injection transformer
*IGBT voltage source inverter
*Fail-safe bypass
*DSP high-speed signal processor
*The AVC-DVR is connected in series between the grid and the protected load. It continuously monitors the input supply voltage, and as soon as it detects a deviation of the supply voltage from the rated level, the AVC-DVR quickly injects an appropriate compensating voltage through the IGBT inverter and the injection transformer.
*The AVC-DVR does not require an energy storage element, as it absorbs the additional energy required from the grid to compensate for the missing voltage.
IGBT Dynamic Voltage Stabiliser Technical Parameters |
|
Model number |
AVC-DVR |
Power (kVA) |
10-1600KVA(3 Phase )/1-30KVA(1Phase ) |
Technology |
PWM-IGBT pulse width modulation technology |
Input |
|
Rated Input Voltage |
3 Phase 400V/ 1Phase 230V(Different voltages are optional) |
Voltage Tolerance |
-%40 , +%20 (Different Voltage Tolerance are optional) |
Frequency |
50 Hz. +/-%5 (60 Hz. Optional) |
输出Output |
|
Rated Output Voltage |
3 Phase 400V/ 1Phase 230V(Different voltages are optional) |
Voltage Tolerance |
+/-1% |
Response Time |
<10ms |
Correction Time |
20-30ms |
Efficiency |
> 98% typical |
Management Monitoring and Communication Interfaces |
|
Display |
Color Touchscreen |
(Show input and output voltage in each phase, P-P & P-L and each phase load) digital display should not affect on AVR Services only show the parameters. |
|
Remote Management Interface(optional) |
Browser-based remote management with Ethernet connectionMOD-BUS RTU with RS485 connection |
Protection Functions |
|
Voltage Protection |
Electronic protection for Low Voltage and High Voltage |
Current Protection |
Input Circuit Breaker(MCCB) (Output Circuit Breaker optional) |
Output Circuit Breaker (optional) |
Output Circuit BreakerACB |
Overload Protection |
1 minute at 125% overload, 10 seconds at 150% overload, at >151% overload the power to the load is cut off after 0.2 seconds. |
OverTemperature Protection |
Fan cooling, working temperature rise of 50K. At 80K, cut off the power supply of the load.
|
Manualbypassswitch(optional) |
(I-0-II) Manual bypass switch for maintenance and fault position (optional) |
Surge Arrester (optional) |
Class-I or Class-II (optional) |
环境条件Environmental Conditions |
|
Operating temperature |
-10°C~+40°C |
AltitudeOperatingHeight |
1500m |
humidity level |
90% none condensed |
Acoustic Noise |
< 55dB (at 1m distance and doors closed) |
Cabinet Specifications |
|
Type –Protection Class |
IP65 |
Paint–Color |
Epoxy-Polyester Powder Paint - RAL 7035(Other colors can be customized) |
Cooling |
Air cooling with thermostat controlled fan |
Three-phase model specification
Model |
Rated current(A) |
Voltage parameters |
Dimension W*D*H |
Remarks |
AVC-DVR-S10KVA |
15 |
Input voltage rangte: ±20% Rated voltage: three phase four wires(L1+L2+L3+N+PE) 380V/400V; |
320*680*760mm
|
|
AVC-DVR-S20KVA |
30 |
|||
AVC-DVR-S30KVA |
46 |
|||
AVC-DVR-S50KVA |
76 |
|||
AVC-DVR-S80KVA |
121 |
600*900*1200mm |
|
|
AVC-DVR-S100KVA |
152 |
|||
AVC-DVR-S150KVA |
228 |
600*900*1400mm |
|
|
AVC-DVR-S180KVA |
273 |
|||
AVC-DVR-S225KVA |
342 |
800*900*1600mm |
||
AVC-DVR-S250KVA |
380 |
|||
AVC-DVR-S320KVA |
486 |
1200*900*1600mm |
||
AVC-DVR-S400KVA |
608 |
|||
AVC-DVR-S500KVA |
760 |
|||
AVC-DVR-S600KVA |
912 |
|||
AVC-DVR-S800KVA |
1216 |
1400*900*1800mm |
|
|
AVC-DVR-S1000KVA |
1520 |
|||
AVC-DVR-S1200KVA |
1824 |
1800*1000*2000mm |
|
|
AVC-DVR-S1400KVA |
2127 |
|||
AVC-DVR-S1600KVA |
2431 |
2400*1000*2000mm |
|
Single phase model specification
Model |
Rated current(A) |
Voltage parameters |
Dimension W*D*H |
Remarks |
AVC-DVR-D3KVA |
13.5 |
Input voltage rangte: ±20% Input voltage: two phase three wires(L1+N+PE) 220V/230V; |
250*480*490mm |
|
AVC-DVR-D5KVA |
22.5 |
|||
AVC-DVR-D10KVA |
45 |
|
||
AVC-DVR-D20KVA |
90 |
|
||
AVC-DVR-D30KVA |
137 |
290*550*560mm |
|
|
AVC-DVR-D50KVA |
228 |
Application scenario
Processing center: laser cutting machine, various machine tools; medical equipment: CT, nuclear magnetic resonance, accelerator; radio and television communication: Radio and television launcher, communication base station; Manor wine making equipment; remote rural power supply; import equipment, high precision equipment protection...